Publications

48건의 Publication
Medical Journal Non-cardiovascular
Artificial intelligence assessment for early detection and prediction of renal impairment using electrocardiography
Although renal failure is a major healthcare burden globally and the cornerstone for preventing its irreversible progression is an early diagnosis, an adequate and noninvasive tool to screen renal impairment (RI) reliably and economically does not exist. We developed an interpretable deep learning model (DLM) using electrocardiography (ECG) and validated its performance. This retrospective cohort study included two hospitals. We included 115,361 patients who had at least one ECG taken with an estimated glomerular filtration rate measurement within 30 min of the index ECG. A DLM was developed using 96,549 ECGs of 55,222 patients. The internal validation included 22,949 ECGs of 22,949 patients. Furthermore, we conducted an external validation with 37,190 ECGs of 37,190 patients from another hospital. The endpoint was to detect a moderate to severe RI (estimated glomerular filtration rate < 45 ml/min/1.73m2). The area under the receiver operating characteristic curve (AUC) of a DLM using a 12-lead ECG for detecting RI during the internal and external validation was 0.858 (95% confidence interval 0.851–0.866) and 0.906 (0.900–0.912), respectively. In the initial evaluation of 25,536 individuals without RI patients whose DLM was defined as having a higher risk had a significantly higher chance of developing RI than those in the low-risk group (17.2% vs. 2.4%, p < 0.001). The sensitivity map indicated that the DLM focused on the QRS complex and T-wave for detecting RI. The DLM demonstrated high performance for RI detection and prediction using 12-, 6-, single-lead ECGs.
International Urology and Nephrology
April 11, 2022
원본보기(새창)
Medical Journal Non-cardiovascular
Electrocardiographic biomarker based on machine learning for detecting overt hyperthyroidism
Although overt hyperthyroidism adversely affects a patient’s prognosis, thyroid function tests (TFTs) are not routinely conducted. Furthermore, vague symptoms of hyperthyroidism often lead to hyperthyroidism being overlooked. An electrocardiogram (ECG) is a commonly used screening test, and the association between thyroid function and ECG is well known. However, it is difficult for clinicians to detect hyperthyroidism through subtle ECG changes. For early detection of hyperthyroidism, we aimed to develop and validate an electrocardiographic biomarker based on a deep learning model (DLM) for detecting hyperthyroidism. This multicentre retrospective cohort study included patients who underwent ECG and TFTs within 24 h. For model development and internal validation, we obtained 174 331 ECGs from 113 194 patients. We extracted 48 648 ECGs from 33 478 patients from another hospital for external validation. Using 500 Hz raw ECG, we developed a DLM with 12-lead, 6-lead (limb leads, precordial leads), and single-lead (lead I) ECGs to detect overt hyperthyroidism. We calculated the model’s performance on the internal and external validation sets using the area under the receiver operating characteristic curve (AUC). The AUC of the DLM using a 12-lead ECG was 0.926 (0.913–0.94) for internal validation and 0.883(0.855–0.911) for external validation. The AUC of DLMs using six and a single-lead were in the range of 0.889–0.906 for internal validation and 0.847–0.882 for external validation. CWe developed a DLM using ECG for non-invasive screening of overt hyperthyroidism. We expect this model to contribute to the early diagnosis of diseases and improve patient prognosis.
European Heart Journal-Digital Health
April 20, 2022
원본보기(새창)
Medical Journal Non-cardiovascular
Deep learning algorithm to predict need for critical care in pediatric emergency departments
Emergency department (ED) overcrowding is a national crisis in which pediatric patients are often prioritized at lower levels. Because the prediction of prognosis for pediatric patients is important but difficult, we developed and validated a deep learning algorithm to predict the need for critical care in pediatric EDs. We conducted a retrospective observation cohort study using data from the Korean National Emergency Department Information System, which collected data in real time from 151 EDs. The study subjects were pediatric patients who visited EDs from 2014 to 2016. The data were divided by date into derivation and test data. The primary end point was critical care, and the secondary endpoint was hospitalization. We used age, sex, chief complaint, symptom onset to arrival time, arrival mode, trauma, and vital signs as predicted variables. The study subjects consisted of 2,937,078 pediatric patients of which 18,253 were critical care and 375,078 were hospitalizations. For critical care, the area under the receiver operating characteristics curve of the deep learning algorithm was 0.908 (95% confidence interval, 0.903-0.910). This result significantly outperformed that of the pediatric early warning score (0.812 [0.803-0.819]), conventional triage and acuity system (0.782 [0.773-0.790]), random forest (0.881 [0.874-0.890]), and logistic regression (0.851 [0.844-0.858]). For hospitalization, the deep-learning algorithm (0.782 [0.780-0.783]) significantly outperformed the other methods. The deep learning algorithm predicted the critical care and hospitalization of pediatric ED patients more accurately than the conventional early warning score, triage tool, and machine learning methods.
Pediatric emergency care
December, 2021
원본보기(새창)
Medical Journal Cardiovascular
Artificial intelligence algorithm for screening heart failure with reduced ejection fraction using electrocardiography
Although heart failure with reduced ejection fraction (HFrEF) is a common clinical syndrome and can be modified by the administration of appropriate medical therapy, there is no adequate tool available to perform reliable, economical, early-stage screening. To meet this need, we developed an interpretable artificial intelligence (AI) algorithm for HFrEF screening using electrocardiography (ECG) and validated its performance. This retrospective cohort study included two hospitals. An AI algorithm based on a convolutional neural network was developed using 39,371 ECG results from 17,127 patients. The internal validation included 3,470 ECGs from 2,908 patients. Furthermore, we conducted external validation using 4,362 ECGs from 4,176 patients from another hospital to verify the applicability of the algorithm across different centers. The end-point was to detect HFrEF, defined as an ejection fraction <40%. We also visualized the regions in 12 lead ECG that affected HFrEF detection in the AI algorithm and compared this to the previously documented literature. During the internal and external validation, the areas under the curves of the AI algorithm using a 12 lead ECG for detecting HFrEF were 0.913 (95% confidence interval, 0.902–0.925) and 0.961 (0.951–0.971), respectively, and the areas under the curves of the AI algorithm using a single-lead ECG were 0.874 (0.859–0.890) and 0.929 (0.911–0.946), respectively. The deep learning-based AI algorithm performed HFrEF detection well using not only a 12 lead but also a single-lead ECG. These results suggest that HFrEF can be screened not only using a 12 lead ECG, as is typical of a conventional ECG machine, but also with a single-lead ECG performed by a wearable device employing the AI algorithm, thereby preventing irreversible disease progression and mortality.
ASAIO Journal
March, 2021
원본보기(새창)
Medical Journal Cardiovascular
Explainable artificial intelligence to detect atrial fibrillation using electrocardiogram
Early detection and intervention of atrial fibrillation (AF) is a cornerstone for effective treatment and prevention of mortality. Diverse deep learning models (DLMs) have been developed, but they could not be applied in clinical practice owing to their lack of interpretability. We developed an explainable DLM to detect AF using ECG and validated its performance using diverse formats of ECG. We conducted a retrospective study. The Sejong ECG dataset comprising 128,399 ECGs was used to develop and internally validated the explainable DLM. DLM was developed with two feature modules, which could describe the reason for DLM decisions. DLM was external validated using data from 21,837, 10,605, and 8528 ECGs from PTB-XL, Chapman, and PhysioNet non-restricted datasets, respectively. The predictor variables were digitally stored ECGs, and the endpoints were AFs. During internal and external validation of the DLM, the area under the receiver operating characteristic curves (AUCs) of the DLM using a 12‑lead ECG in detecting AF were 0.997-0.999. The AUCs of the DLM with VAE using a 6‑lead and single‑lead ECG were 0.990-0.999. The AUCs of explainability about features such as rhythm irregularity and absence of P-wave were 0.961-0.993 and 0.983-0.993, respectively. Our DLM successfully detected AF using diverse ECGs and described the reason for this decision. The results indicated that an explainable artificial intelligence methodology could be adopted to the DLM using ECG and enhance the transparency of the DLM for its application in clinical practice.
International Journal of Cardiology
November 30, 2020
원본보기(새창)
Medical Journal Cardiovascular
Artificial intelligence assessment for early detection of heart failure with preserved ejection fraction based on electrocardiographic features
Although heart failure with preserved ejection fraction (HFpEF) is a rapidly emerging global health problem, an adequate tool to screen it reliably and economically does not exist. We developed an interpretable deep learning model (DLM) using electrocardiography (ECG) and validated its performance. This retrospective cohort study included two hospitals. 34 103 patients who underwent echocardiography and ECG within 1 week and indicated normal left ventricular systolic function were included in this study. A DLM based on an ensemble neural network was developed using 32 671 ECGs of 20 169 patients. The internal validation included 1979 ECGs of 1979 patients. Furthermore, we conducted an external validation with 11 955 ECGs of 11955 patients from another hospital. The endpoint was to detect HFpEF. During the internal and external validation, the area under the receiver operating characteristic curves of a DLM using 12-lead ECG for detecting HFpEF were 0.866 (95% confidence interval 0.850–0.883) and 0.869 (0.860–0.877), respectively. In the 1412 individuals without HFpEF at initial echocardiography, patients whose DLM was defined as having a higher risk had a significantly higher chance of developing HFpEF than those in the low-risk group (33.6% vs. 8.4%, P < 0.001). Sensitivity map showed that the DLM focused on the QRS complex and T-wave. The DLM demonstrated high performance for HFpEF detection using not only a 12-lead ECG but also 6- single lead ECG. These results suggest that HFpEF can be screened using conventional ECG devices and diverse life-type ECG machines employing the DLM, thereby preventing disease progression.
European Heart Journal-Digital Health
December 10, 2020
원본보기(새창)
Medical Journal Non-cardiovascular
Deep-learning model for screening sepsis using electrocardiography
Sepsis is a life-threatening organ dysfunction and a major healthcare burden worldwide. Although sepsis is a medical emergency that requires immediate management, screening for the occurrence of sepsis is difficult. Herein, we propose a deep learning-based model (DLM) for screening sepsis using electrocardiography (ECG). This retrospective cohort study included 46,017 patients who were admitted to two hospitals. A total of 1,548 and 639 patients had sepsis and septic shock, respectively. The DLM was developed using 73,727 ECGs from 18,142 patients, and internal validation was conducted using 7774 ECGs from 7,774 patients. Furthermore, we conducted an external validation with 20,101 ECGs from 20,101 patients from another hospital to verify the applicability of the DLM across centers. During the internal and external validations, the area under the receiver operating characteristic curve (AUC) of the DLM using 12-lead ECG was 0.901 (95% confidence interval, 0.882-0.920) and 0.863 (0.846-0.879), respectively, for screening sepsis and 0.906 (95% confidence interval (CI), 0.877-0.936) and 0.899 (95% CI, 0.872-0.925), respectively, for detecting septic shock. The AUC of the DLM for detecting sepsis using 6-lead and single-lead ECGs was 0.845-0.882. A sensitivity map revealed that the QRS complex and T waves were associated with sepsis. Subgroup analysis was conducted using ECGs from 4,609 patients who were admitted with an infectious disease, and the AUC of the DLM for predicting in-hospital mortality was 0.817 (0.793-0.840). There was a significant difference in the prediction score of DLM using ECG according to the presence of infection in the validation dataset (0.277 vs. 0.574, p < 0.001), including severe acute respiratory syndrome coronavirus 2 (0.260 vs. 0.725, p = 0.018). The DLM delivered reasonable performance for sepsis screening using 12-, 6-, and single-lead ECGs. The results suggest that sepsis can be screened using not only conventional ECG devices but also diverse life-type ECG machines employing the DLM, thereby preventing irreversible disease progression and mortality.
Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine
October 03, 2021
원본보기(새창)
Medical Journal Cardiovascular
Artificial intelligence to diagnose paroxysmal supraventricular tachycardia using electrocardiography during normal sinus rhythm
Paroxysmal supraventricular tachycardia (PSVT) is not detected owing to its paroxysmal nature, but it is associated with the risk of cardiovascular disease and worsens the patient quality of life. A deep learning model (DLM) was developed and validated to identify patients with PSVT during normal sinus rhythm in this multicentre retrospective study. This study included 12 955 patients with normal sinus rhythm, confirmed by a cardiologist. A DLM was developed using 31 147 electrocardiograms (ECGs) of 9069 patients from one hospital. We conducted an accuracy test with 13 753 ECGs of 3886 patients from another hospital. The DLM was developed based on residual neural network. Digitally stored ECG were used as predictor variables and the outcome of the study was ability of the DLM to identify patients with PSVT using an ECG during sinus rhythm. We employed a sensitivity map method to identify an ECG region that had a significant effect on developing PSVT. During accuracy test, the area under the receiver operating characteristic curve of a DLM using a 12-lead ECG for identifying PSVT patients during sinus rhythm was 0.966 (0.948–0.984). The accuracy, sensitivity, specificity, positive predictive value, and negative predictive value of DLM were 0.970, 0.868, 0.972, 0.255, and 0.998, respectively. The DLM showed delta wave and QT interval were important to identify the PSVT. The proposed DLM demonstrated a high performance in identifying PSVT during normal sinus rhythm. Thus, it can be used as a rapid, inexpensive, point-of-care means of identifying PSVT in patients.
European Heart Journal-Digital Health
February 09, 2021
원본보기(새창)
Medical Journal Non-cardiovascular
Artificial intelligence for detecting electrolyte imbalance using electrocardiography
The detection and monitoring of electrolyte imbalance is essential for appropriate management of many metabolic diseases; however, there is no tool that detects such imbalances reliably and noninvasively. In this study, we developed a deep learning model (DLM) using electrocardiography (ECG) for detecting electrolyte imbalance and validated its performance in a multicenter study. This retrospective cohort study included two hospitals: 92,140 patients who underwent a laboratory electrolyte examination and an ECG within 30 min were included in this study. A DLM was developed using 83,449 ECGs of 48,356 patients; the internal validation included 12,091 ECGs of 12,091 patients. We conducted an external validation with 31,693 ECGs of 31,693 patients from another hospital, and the result was electrolyte imbalance detection. During internal, the area under the receiving operating characteristic curve (AUC) of a DLM using a 12-lead ECG for detecting hyperkalemia, hypokalemia, hypernatremia, hyponatremia, hypercalcemia, and hypocalcemia were 0.945, 0.866, 0.944, 0.885, 0.905, and 0.901, respectively. The values during external validation of the AUC of hyperkalemia, hypokalemia, hypernatremia, hyponatremia, hypercalcemia, and hypocalcemia were 0.873, 0.857, 0.839, 0.856, 0.831, and 0.813 respectively. The DLM helped to visualize the important ECG region for detecting each electrolyte imbalance, and it showed how the P wave, QRS complex, or T wave differs in importance in detecting each electrolyte imbalance. The proposed DLM demonstrated high performance in detecting electrolyte imbalance. These results suggest that a DLM can be used for detecting and monitoring electrolyte imbalance using ECG on a daily basis.
Annals of Noninvasive Electrocardiology
March 15, 2021
원본보기(새창)
Medical Journal Non-cardiovascular
Artificial intelligence using electrocardiography: strengths and pitfalls
메이요클리닉 논문에 대한 서평 논문으로서 심전도AI의 장점과 한계를 기술
European Heart Journal
March 22, 2021